Chapter 18 Classifier
GS3700/XGS3700 Series User’s Guide
166
18.3 Viewing and Editing Classifier Configuration
To view a summary of the classifier configuration, scroll down to the summary table at the bottom
of the Classifier screen. To change the settings of a rule, click a number in the Index field.
Note: When two rules conflict with each other, a higher layer rule has priority over a lower
layer rule.
Figure 98 Advanced Application > Classifier: Summary Table
The following table describes the labels in this screen.
Destination
IP Address/
Address
Prefix
Enter a destination IP address in dotted decimal notation.
Specify the address prefix by entering the number of ones in the subnet mask.
Socket
Number
Note: You must select either UDP or TCP in the IP Protocol field before you configure the
socket numbers.
Select Any to apply the rule to all TCP/UDP protocol port numbers or select the second
option and enter a TCP/UDP protocol port number.
Add Click this to create a new entry or to update an existing one.
This saves your changes to the Switch’s run-time memory. The Switch loses these changes if it
is turned off or loses power, so use the Save link on the top navigation panel to save your
changes to the non-volatile memory when you are done configuring.
Cancel Click Cancel to begin configuring this screen afresh.
Clear Click Clear to set the above fields back to the factory defaults.
Table 69 Advanced Application > Classifier (continued)
LABEL DESCRIPTION
Table 70 Classifier: Summary Table
LABEL DESCRIPTION
Index This field displays the index number of the rule. Click an index number to edit the rule.
Active This field displays Yes when the rule is activated and No when it is deactivated.
Name This field displays the descriptive name for this rule. This is for identification purposes only.
Rule This field displays a summary of the classifier rule’s settings.
Delete Click Delete to remove the selected entry from the summary table.
Cancel Click Cancel to clear the Delete check boxes.