The data is communicated between the PLC1 and PLC2 devices in the following
way:
1. PLC1 and PLC2 put in place an estimate of the transmission channel (modu-
lation levels, error coding level, and so forth).
2. PLC1 and PLC2 inform CCo (PLC3) that they wish to exchange data.
3. CCo (PLC3) allocates to them a time interval during which they have access
to the medium.
4. PLC1 and PLC2 directly exchange their data without going via CCo.
Network Mode Functionality 37
Figure 3.3 Organization of a PLC network in the peer-to-peer mode
Figure 3.4 Architecture of a PLC network in centralized mode