11. System Parameter Specification
MSAP2000 Technical Manual V3.0 11-7
11.5. POTS
Parameter FXO(COT POTS) FXS (RT POTS)
Subscriber Phone
Signaling format
Dial Pulse (DP) and Dual Tone Multiple
Frequency (DTMF)
Signaling Transmission
Format
Channel Associated Signaling (CAS) or
Common Channel Signaling (CCS)
Caller ID Display (See
“Note” below)
DTMF and FSK
Impedance (balanced) 900 Nominal 600 Nominal
Line Code ITU-T G.711 A-law
Subscriber-end (RT)
Ring Format
220Hz, 60 Vrms (±10V).
One second on, two seconds off
(configurable)
Polarity Reversal Polarity Guard Polarity Reversal
Detection
Minimum startup
voltage required for RT
20mA. The DC loop
resistance is 1200
(including internal
phone resistance)
Voice Mailbox Complies with Chunghwa Telecom’s ME
7230-2: System Specifications for
Telephone Voice Mailboxes
Messaging Services Transparently transmits the messages
between Exchange Servers and
Telephones
Standard
Specification
(Table 11-A)
Note: Supports CENTREX, caller ID, and complies with CHT
ME2420-2: Specification for Caller ID Frequency Shift Keying (FSK)