Zyxel-communications Multi-service Access Platform MSAP2000 Manuel d'utilisateur Page 1

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Accessoires pour ordinateurs Zyxel-communications Multi-service Access Platform MSAP2000. ZyXEL Communications Multi-service Access Platform MSAP2000 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 243
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs

Résumé du contenu

Page 1 - Technical Manual

ZyXEL Multi-Services Access Platform MSAP2000 Technical Manual V3R0

Page 2 - ZyXEL Technologies Inc

1. System Introduction MSAP2000 Technical Manual V3.0 i Table of Contents 1. System Introduction ...

Page 3

6. System Design MSAP2000 Technical Manual V3.0 6-3 6.2. Clock Synchronization COT Timing The MSAP2000 provides two Building Integrated Timing Sup

Page 4 - About This Manual

6. System Design MSAP2000 Technical Manual V3.0 6-4 6.3. Redundancy and Protection Design Overview MSAP2000 universal shelf allows most of the mod

Page 5 - Environmental Protection

6. System Design MSAP2000 Technical Manual V3.0 6-5 E1 link goes down, total traffic for all the subscribers’ module (FXS) will be divided evenly

Page 6

6. System Design MSAP2000 Technical Manual V3.0 6-6 6.4. Reliability MTBF The devices and quality testing procedures applied towards MSAP2000 Modu

Page 7

6. System Design MSAP2000 Technical Manual V3.0 6-7 6.5. Ethernet over SDH Design MSAP2000’s C/REoSM combines two Protocols: ITU-T G.7041 Generic

Page 8

6. System Design MSAP2000 Technical Manual V3.0 6-8 6.6. IP DSLAM Design GbE when associated with xDSL service card like AAM can provide the IP D

Page 9

7. Product Specification MSAP2000 Technical Manual V3.0 7-i Table of Contents 7. Product Specification...

Page 10 - Table of Contents

7. Product Specification MSAP2000 Technical Manual V3.0 7-ii

Page 11 - THIS PAGE IS LEFT BLANK

7. Product Specification MSAP2000 Technical Manual V3.0 7-1 7. Product Specification 7.1. Overview This section provides a detailed introduct

Page 12 - 1. System Introduction

7. Product Specification MSAP2000 Technical Manual V3.0 7-2 7.2. Main Components A complete MSAP2000 System consists of the following component

Page 13 - 1.2. Key Features

1. System Introduction MSAP2000 Technical Manual V3.0 ii THIS PAGE IS LEFT BLANK

Page 14

7. Product Specification MSAP2000 Technical Manual V3.0 7-3 Network Management System The Main Processing Module’s (MPM) built-in SNMP agent he

Page 15

7. Product Specification MSAP2000 Technical Manual V3.0 7-4 7.3. Common Shelf Overview The common shelf is MSAP2000’s most basic and crucial com

Page 16 - 1.3. System Architecture

7. Product Specification MSAP2000 Technical Manual V3.0 7-5 Shelf Specification DC Input 2 (3-pin EURO-TYPE) External Clock Input 2 (2-pin w

Page 17

7. Product Specification MSAP2000 Technical Manual V3.0 7-6 Front View Rear View

Page 18 - 1.5. Testing and maintenance

7. Product Specification MSAP2000 Technical Manual V3.0 7-7 7.4. Central Office Power Supply Module (CoPSM) Overview The Central Office Power Su

Page 19

7. Product Specification MSAP2000 Technical Manual V3.0 7-8 CoPSM Specification Minimum input voltage -36 VDC (-42VDC optional) Recommended i

Page 20

7. Product Specification MSAP2000 Technical Manual V3.0 7-9 CoPSM Panel View LED Status Description PWR (Green) ON: CoPSM input/output pow

Page 21 - 2. System Architecture

7. Product Specification MSAP2000 Technical Manual V3.0 7-10 7.5. Remote Terminal Power Supply Module (RtPSM) Overview The Remote Terminal Power

Page 22 - 2.2. SDH ADM

7. Product Specification MSAP2000 Technical Manual V3.0 7-11 RtPSM Specification Minimum input voltage -36 VDC (-42VDC optional) Recommended

Page 23 - 2.3. NG DLC

7. Product Specification MSAP2000 Technical Manual V3.0 7-12 RtPSM Panel View LED Status Description PWR (Green) ON: RtPSM input/output po

Page 24

1. System Introduction MSAP2000 Technical Manual V3.0 1-1 1. System Introduction 1.1. Overview MSAP2000 is a next generation access platform, w

Page 25 - 2.4. E1 Multiplexer

7. Product Specification MSAP2000 Technical Manual V3.0 7-13 7.6. Main Processing Module (MPM) Overview The Main Processing Module (MPM) provide

Page 26 - 2.5. IP DSLAM

7. Product Specification MSAP2000 Technical Manual V3.0 7-14 MPM Specification Microprocessor Intel IXP42xXscale-based Flash Flash EPROM (4MB

Page 27 - 2.6. Gigabit Switch

7. Product Specification MSAP2000 Technical Manual V3.0 7-15 MPM Panel View LED Status Description ACTV/STBY Green: MPM in use (Green/Oran

Page 28 - 2.7. VoIP Gateway

7. Product Specification MSAP2000 Technical Manual V3.0 7-16 7.7. Expansion Link Module (ELM) Overview The Expansion Link Module (ELM) co-works

Page 29

7. Product Specification MSAP2000 Technical Manual V3.0 7-17 ELM Specification Microprocessor Winbond W90N740 Flash ROM Flash EPROM (1MB) Ha

Page 30 - 2.8. Layer 2 Switch

7. Product Specification MSAP2000 Technical Manual V3.0 7-18 ELM Panel View LED Status Description ACTV/STBY Green: Functioning normally (

Page 31 - 2.9. Digital Cross Connect

7. Product Specification MSAP2000 Technical Manual V3.0 7-19 7.8. Expansion Processing Module (EPM) Overview The Expansion Processing Module (EP

Page 32 - 2.10. Flexible Topology

7. Product Specification MSAP2000 Technical Manual V3.0 7-20 EPM Specification Microprocessor Winbond W90N740 Flash ROM Flash EPROM (1MB) Ha

Page 33

7. Product Specification MSAP2000 Technical Manual V3.0 7-21 EPM Panel View LED Status Description ACTV/STBY Green: Functioning normally (

Page 34 - 2.11. Local Craft Terminal

7. Product Specification MSAP2000 Technical Manual V3.0 7-22 7.9. Metallic Line Testing Module (MLTM) Overview The Metallic Line Testing Module

Page 35

1. System Introduction MSAP2000 Technical Manual V3.0 1-2 1.2. Key Features Multi-service Provision: Voice, Data, Video in one Shelf MSAP2000 is a

Page 36

7. Product Specification MSAP2000 Technical Manual V3.0 7-23 MLTM Specification Microprocessor WINBOND W90N740 Flash ROM Flash (2MKB) Hardw

Page 37

7. Product Specification MSAP2000 Technical Manual V3.0 7-24 MLTM Panel View LED Status Description ACTV (Green) Green: Functioning normal

Page 38

7. Product Specification MSAP2000 Technical Manual V3.0 7-25 7.10. V5.2 Processing Module (V5P) Overview The V5.2 Processing Module (V5P) is th

Page 39 - 3. Application and Services

7. Product Specification MSAP2000 Technical Manual V3.0 7-26 V5P Specification Microprocessor INTEL IXP42x Xscale Flash ROM Flash EPROM(2MB) R

Page 40

7. Product Specification MSAP2000 Technical Manual V3.0 7-27 V5P Product View LED Status Description ACTV (Green) STBY (Yellow) Green ON: P

Page 41

7. Product Specification MSAP2000 Technical Manual V3.0 7-28 7.11. Packet Voice Module (PVM) Overview The Packet Voice Module (PVM) enables MSA

Page 42 - 3.4. Optical Transportation

7. Product Specification MSAP2000 Technical Manual V3.0 7-29 PVM Specification Microprocessor Intel IXP42x Xscale-based Flash Flash EPROM (8M

Page 43

7. Product Specification MSAP2000 Technical Manual V3.0 7-30 PVM Panel View LED Status Description ACTV/STBY Green: PVM in use (Green/Oran

Page 44

7. Product Specification MSAP2000 Technical Manual V3.0 7-31 7.12. STM-1 Module (SM1) Overview The STM-1 Module (SM1), like OIM, provides stand

Page 45

7. Product Specification MSAP2000 Technical Manual V3.0 7-32 SM1 Specification Microprocessor Winbond W90N70 Flash Flash EPROM (1MB) Hardwar

Page 46

1. System Introduction MSAP2000 Technical Manual V3.0 1-3 The following modules come with 1:1 redundancy functions:  Power Supply Module: CoPS

Page 47

7. Product Specification MSAP2000 Technical Manual V3.0 7-33 SM1 Panel View LED Status Description ACTV/STBY Green: Functioning normally (

Page 48

7. Product Specification MSAP2000 Technical Manual V3.0 7-34 7.13. STM-4 Module (SM4) Overview The STM-4 Module (SM4) provides standard SDH STM

Page 49

7. Product Specification MSAP2000 Technical Manual V3.0 7-35 SM4 Specification Microprocessor Winbond W90N70 Flash Flash EPROM (1MB) Hardwar

Page 50

7. Product Specification MSAP2000 Technical Manual V3.0 7-36 SM4 Panel View LED Status Description ACTV/STBY Green: Functioning normally (

Page 51

7. Product Specification MSAP2000 Technical Manual V3.0 7-37 7.14. Optical Interface Module (OIM) Overview The Optical Interface Module (OIM) p

Page 52 - 4. System Components

7. Product Specification MSAP2000 Technical Manual V3.0 7-38 OIM Specification Microprocessor Winbond W90N70 Flash Flash EPROM (1MB) Hardwar

Page 53 - 4.2. Terminal

7. Product Specification MSAP2000 Technical Manual V3.0 7-39 OIM Panel View LED Status Description ACTV/STBY Green: Functioning normally (

Page 54 - 4.3. Shelf

7. Product Specification MSAP2000 Technical Manual V3.0 7-40 7.15. Quad E1 Module (QE1M) Overview Within MSAP2000, the QuadE1 Module (QE1M) can

Page 55

7. Product Specification MSAP2000 Technical Manual V3.0 7-41 QE1M Specification Microprocessor Winbond W90N740 Flash ROM Flash EPROM (1MB) H

Page 56

7. Product Specification MSAP2000 Technical Manual V3.0 7-42 QE1M Panel View LED Status Description ACTV (Green) Green: Functioning norma

Page 57 - 4.4. Common Control Modules

1. System Introduction MSAP2000 Technical Manual V3.0 1-4 Network Management System(NMS) MSAP2000’s OptiCore™, is a highly integrated and easy-

Page 58

7. Product Specification MSAP2000 Technical Manual V3.0 7-43 7.16. Foreign Exchange Office Module (FXO) Overview The Foreign Exchange Office Mod

Page 59 - 4.5. Trunk Interface Module

7. Product Specification MSAP2000 Technical Manual V3.0 7-44 FXO Specification Microprocessor Samsung S3F441FX Flash ROM Flash (256KB) Hardw

Page 60

7. Product Specification MSAP2000 Technical Manual V3.0 7-45 FXO Panel View LED Status Description ACTV (Green) Green: Functioning normall

Page 61

7. Product Specification MSAP2000 Technical Manual V3.0 7-46 7.17. Foreign Exchange Station Module (FXS) Overview The Foreign Exchange Station

Page 62

7. Product Specification MSAP2000 Technical Manual V3.0 7-47 FXS Specification Microprocessor Samsung S3F441FX Flash ROM Flash (256KB) Hardw

Page 63

7. Product Specification MSAP2000 Technical Manual V3.0 7-48 FXS Panel View LED Status Description ACTV (Green) Green: Functioning normall

Page 64

7. Product Specification MSAP2000 Technical Manual V3.0 7-49 7.18. Foreign Exchange Office Payphone Module (FXO-P) Overview The Foreign Exchange

Page 65

7. Product Specification MSAP2000 Technical Manual V3.0 7-50 FXO-P Specification Microprocessor Samsung S3F441FX Flash ROM Flash (256KB) Har

Page 66

7. Product Specification MSAP2000 Technical Manual V3.0 7-51 FXO-P Panel View LED Status Description ACTV (Green) Green: Functioning norma

Page 67 - 4.9. Indoor Rack

7. Product Specification MSAP2000 Technical Manual V3.0 7-52 7.19. Foreign Exchange Station Payphone Module (FXS-P) Overview The Foreign Exchan

Page 68

1. System Introduction MSAP2000 Technical Manual V3.0 1-5 1.3. System Architecture Scalability MSAP2000 is mounted on a 19-inch shelf, which can b

Page 69

7. Product Specification MSAP2000 Technical Manual V3.0 7-53 FXS-P Specification Microprocessor Samsung S3F441FX Flash ROM Flash (256KB) Har

Page 70

7. Product Specification MSAP2000 Technical Manual V3.0 7-54 FXS-P Panel View LED Status Description ACTV (Green) Green: Functioning norma

Page 71 - 5. System Configuration

7. Product Specification MSAP2000 Technical Manual V3.0 7-55 7.20. 2W/4W Ear and Mouth Module (2W/4W E&M) Overview The 2W/4W Ear and Mouth

Page 72

7. Product Specification MSAP2000 Technical Manual V3.0 7-56 E&M Specification Microprocessor Samsung S3F441FX Flash ROM Flash (256KB) H

Page 73 - 5.1. Slot Chart

7. Product Specification MSAP2000 Technical Manual V3.0 7-57 E&M Panel View LED Status Description ACTV (Green) Green: Functioning nor

Page 74 - 5.2. Module Capacity

7. Product Specification MSAP2000 Technical Manual V3.0 7-58 7.21. G.SHDSL Module (GSH) Overview The G.SHDSL Module (GSH) is a trunk or subscr

Page 75

7. Product Specification MSAP2000 Technical Manual V3.0 7-59 Application The GSH is used when the symmetrical bandwidth through twisted pair is

Page 76

7. Product Specification MSAP2000 Technical Manual V3.0 7-60 GSH Specification Microprocessor Winbond W90N740 Flash ROM Flash EPROM(1MB) Har

Page 77

7. Product Specification MSAP2000 Technical Manual V3.0 7-61 GSH Panel View LED Status Description ACTV (Green) Green: Functioning normall

Page 78

7. Product Specification MSAP2000 Technical Manual V3.0 7-62 7.22. U Interface Network Terminal Module (ISDN-U LUNT) Overview The U Interface

Page 79

1. System Introduction MSAP2000 Technical Manual V3.0 1-6 1.4. Applications and Services MSAP2000 is mainly applied towards Access Networks, to e

Page 80

7. Product Specification MSAP2000 Technical Manual V3.0 7-63 LUNT Specification Microprocessor Winbond W90N740 Flash ROM Flash EPROM(1MB) Ha

Page 81

7. Product Specification MSAP2000 Technical Manual V3.0 7-64 LUNT Panel View LED Status Description ACTV (Green) Green: Functioning normal

Page 82

7. Product Specification MSAP2000 Technical Manual V3.0 7-65 7.23. ISDN U Interface Line Terminal Module (ISDN-U LULT) Overview The ISDN U Int

Page 83

7. Product Specification MSAP2000 Technical Manual V3.0 7-66 LULT Specification Microprocessor Winbond W90N740 Flash ROM Flash EPROM(1MB) Ha

Page 84

7. Product Specification MSAP2000 Technical Manual V3.0 7-67 LULT Panel View LED Status Description ACTV (Green) Green: Functioning normal

Page 85

7. Product Specification MSAP2000 Technical Manual V3.0 7-68 7.24. Nx64 Module for Data Leased Service (N64M) Overview The Nx64 Module (N64M) p

Page 86

7. Product Specification MSAP2000 Technical Manual V3.0 7-69 N64M Specification Microprocessor Winbond W90N740 Flash ROM Flash EPROM(1MB) Ha

Page 87

7. Product Specification MSAP2000 Technical Manual V3.0 7-70 N64M Panel View LED Status Description ACTV (Green) Green: Functioning normal

Page 88

7. Product Specification MSAP2000 Technical Manual V3.0 7-71 7.25. Gigabit Ethernet Module (GbE) Overview The Gigabit Ethernet Module (GbE) pro

Page 89 - Configuration (STM-1)

7. Product Specification MSAP2000 Technical Manual V3.0 7-72 GbE Specification Microprocessor Winbond W90N740 Flash ROM Flash EPROM(1MB) Har

Page 90

1. System Introduction MSAP2000 Technical Manual V3.0 1-7 1.5. Testing and maintenance MSAP2000 is equipped with testing ability for system diag

Page 91 - Configuration

7. Product Specification MSAP2000 Technical Manual V3.0 7-73 GbE Panel View LED Status Description ACTV (Green) ON: Functioning normally O

Page 92

7. Product Specification MSAP2000 Technical Manual V3.0 7-74 7.26. Optical Gigabit Switch(OGS) Overview The Optical Gigabit Switch (OGS) provid

Page 93

7. Product Specification MSAP2000 Technical Manual V3.0 7-75 OGS Specification Microprocessor Winbond W90N740 Flash ROM Flash EPROM(1MB) Har

Page 94

7. Product Specification MSAP2000 Technical Manual V3.0 7-76 OGS Panel View LED Status Description ACTV (Green) ON: Functioning normally O

Page 95

7. Product Specification MSAP2000 Technical Manual V3.0 7-77 7.27. RT Ethernet over SDH Module (REoSM) Overview The REoSM (RT Ethernet over SDH

Page 96

7. Product Specification MSAP2000 Technical Manual V3.0 7-78 REoSM Specification Microprocessor Winbond W90N740 Flash ROM Flash EPROM(1MB) H

Page 97

7. Product Specification MSAP2000 Technical Manual V3.0 7-79 REoSM Panel View LED Status Description ACTV (Green) Green: Functioning norma

Page 98

7. Product Specification MSAP2000 Technical Manual V3.0 7-80 7.28. COT Ethernet over SDH Module (CEoSM) Overview The CEoSM (COT Ethernet over S

Page 99

7. Product Specification MSAP2000 Technical Manual V3.0 7-81 CEoSM Specification Microprocessor Winbond W90N740 Flash ROM Flash EPROM(1MB) H

Page 100 - 6.2. Clock Synchronization

7. Product Specification MSAP2000 Technical Manual V3.0 7-82 CEoSM Panel View LED Status Description ACTV (Green) Green: Functioning norma

Page 101 - 6. System Design

2. System Architecture MSAP2000 Technical Manual V3.0 i Table of Contents 2. System Architecture...

Page 102

7. Product Specification MSAP2000 Technical Manual V3.0 7-83 7.29. Ethernet Module (ETH) Overview The Ethernet Module (ETH) provides a one chan

Page 103 - 6.4. Reliability

7. Product Specification MSAP2000 Technical Manual V3.0 7-84 ETH Specification Microprocessor Winbond W90N740 Flash ROM Flash EPROM(1MB) Har

Page 104

7. Product Specification MSAP2000 Technical Manual V3.0 7-85 ETH Panel View LED Status Description ACTV (Green) Green: Functioning normall

Page 105 - 6.6. IP DSLAM Design

7. Product Specification MSAP2000 Technical Manual V3.0 7-86 7.30. Ethernet Switching Module (ESM) Overview The Ethernet Switching Module (ESM)

Page 106

7. Product Specification MSAP2000 Technical Manual V3.0 7-87 ESM Specification Microprocessor Winbond W90N740 Flash ROM Flash EPROM(1MB) Har

Page 107 - 7. Product Specification

7. Product Specification MSAP2000 Technical Manual V3.0 7-88 ESM Panel View LED Status Description ACTV (Green) Green: Functioning normall

Page 108

7. Product Specification MSAP2000 Technical Manual V3.0 7-89 7.31. ADSL2/2+ Access Module (AAM) Overview The ADSL2/2+ Access Module (AAM) provi

Page 109 - 7.2. Main Components

7. Product Specification MSAP2000 Technical Manual V3.0 7-90 AAM Specification Network processor Wintegra WIN717 Flash Flash EPROM (4MB) Ha

Page 110

7. Product Specification MSAP2000 Technical Manual V3.0 7-91 AAM Panel View LED Status Description ACT(Green) Green: AAM in use FAIL (Re

Page 111 - 7.3. Common Shelf

7. Product Specification MSAP2000 Technical Manual V3.0 7-92 7.32. Passive Mux Module(PMM) Overview In some application, it will cost a lot to h

Page 112

ii ZyXEL MSAP2000 Technical Manual Manual Version English V3 Product Version V3R0 Hardcopy order Information TM-01-V3R0 ZyXEL Technologies Inc. WE

Page 113

2. System Architecture MSAP2000 Technical Manual V3.0 ii THIS PAGE IS LEFT BLANK

Page 114 - Modules CoPSMModules

7. Product Specification MSAP2000 Technical Manual V3.0 7-93 QEToP Specification Local Processor WINBOND W90N740 Flash ROM Flash EPROM(4MB)

Page 115

7. Product Specification MSAP2000 Technical Manual V3.0 7-94 PMM Panel View LED Status Description ACT(Green) Green: PMM in use FAIL (Re

Page 116

7. Product Specification MSAP2000 Technical Manual V3.0 7-95 7.33. G.SHDSL Remote CPE (GSH-R) Overview The G.SHDSL Remote CPE (GSH-R) serves as

Page 117

7. Product Specification MSAP2000 Technical Manual V3.0 7-96 GSH-R Specification Line Code 16-level TC PAM (TC PAM 16) Symbol Rate (Data Rat

Page 118

7. Product Specification MSAP2000 Technical Manual V3.0 7-97 GSH-R Product View LED Status Description PWR (Green) Green: Power source is

Page 119

8. System Management MSAP2000 Technical Manual V3.0 i Table of Contents 8. System Management ...

Page 120

8. System Management MSAP2000 Technical Manual V3.0 i THIS PAGE IS LEFT BLANK

Page 121

8. System Management MSAP2000 Technical Manual V3.0 8-1 8. System Management 8.1. Overview MSAP200 supports different types of system manageme

Page 122

8. System Management MSAP2000 Technical Manual V3.0 8-2 8.2. Local Craft Terminal (LCT) User can connect terminal or PC installed with terminal

Page 123 - Module EPMModule

8. System Management MSAP2000 Technical Manual V3.0 8-3 8.3. Telnet In addition to the LCT, the same menu-driven mode through the Telnet is also

Page 124

2. System Architecture MSAP2000 Technical Manual V3.0 2-1 2. System Architecture 2.1. Overview Multiple Elements on a Single Shelf MSAP2000 ha

Page 125

8. System Management MSAP2000 Technical Manual V3.0 8-4 8.4. OptiCore™ Network Management System (NMS) Overview OptiCore™ is a Network Management

Page 126 - ELM MPMModule

8. System Management MSAP2000 Technical Manual V3.0 8-5 Client, or web browsers such as IE or Netscape. Installation Requirements The OptiCore Net

Page 127

8. System Management MSAP2000 Technical Manual V3.0 8-6 THIS PAGE IS LEFT BLANK

Page 128

9. Network Management System (NMS) Functions MSAP2000 Technical Manual V3.0 i Table of Contents 9. NMS Management Functions...

Page 129

9. Network Management System (NMS) Functions MSAP2000 Technical Manual V3.0 i THIS PAGE IS LEFT BLANK

Page 130

9. Network Management System (NMS) Functions MSAP2000 Technical Manual V3.0 9-1 9. NMS Management Functions 9.1. Overview MSAP2000 supports both

Page 131

9. Network Management System (NMS) Functions MSAP2000 Technical Manual V3.0 9-2 9.2. Configuration OptiCore™’s Configuration function allows the

Page 132

9. Network Management System (NMS) Functions MSAP2000 Technical Manual V3.0 9-3 9.3. Performance Monitoring (PM) Performance Monitoring is when

Page 133

9. Network Management System (NMS) Functions MSAP2000 Technical Manual V3.0 9-4 9.4. Fault Management (FM) The Fault Management (FM) function au

Page 134

9. Network Management System (NMS) Functions MSAP2000 Technical Manual V3.0 9-5 LEDs on the faceplate of the MPM Module can indicate power alarms,

Page 135

2. System Architecture MSAP2000 Technical Manual V3.0 2-2 error codes in any channel. Not only does this function help towards network maintenanc

Page 136

9. Network Management System (NMS) Functions MSAP2000 Technical Manual V3.0 9-6 9.5. Maintenance MSAP2000 supports the following test functions:

Page 137

9. Network Management System (NMS) Functions MSAP2000 Technical Manual V3.0 9-7 Other Test Items:  V-Port Distinction Testing  Monitoring Only

Page 138 - 7.12. STM-1 Module (SM1)

9. Network Management System (NMS) Functions MSAP2000 Technical Manual V3.0 9-8 Loopback Testing All RT Modules support Channel Loopback function

Page 139

9. Network Management System (NMS) Functions MSAP2000 Technical Manual V3.0 9-9 9.6. Security OptiCore™ NMS maintains System Database security b

Page 140

10. System Power and Operation Environment MSAP2000 Technical Manual V3.0 i Table of Contents 10. System Power and Operation Environment...

Page 141 - 7.13. STM-4 Module (SM4)

10. System Power and Operation Environment MSAP2000 Technical Manual V3.0 i THIS PAGE IS LEFT BLANK

Page 142

10. System Power and Operation Environment MSAP2000 Technical Manual V3.0 10-1 10. System Power and Operation Environment 10.1. System Power COT

Page 143

10. System Power and Operation Environment MSAP2000 Technical Manual V3.0 10-2 10.2. Environment Conditions MSAP2000 components can function norm

Page 144

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-i Table of Contents 11. System Parameter Specification ...

Page 145

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-ii THIS PAGE IS LEFT BLANK

Page 146

2. System Architecture MSAP2000 Technical Manual V3.0 2-3 2.3. NG DLC As a legacy Digital Loop Carrier (DLC), MSAP2000 uses European-standard PC

Page 147 - 7.15. Quad E1 Module (QE1M)

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-1 11. System Parameter Specification This chapter will list those parameter

Page 148

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-2 11.2. STM-4 The following parameters will apply to module of SM4 (7.13).

Page 149

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-3 11.3. Gigabit The following parameters will apply to modules of GbE (7.25)

Page 150

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-4 11.4. E1 The following parameters will apply to modules of QE1M (7.15) S

Page 151

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-5 Pulse Shape Complies with ITU-T G.703 recommended standards. Output sig

Page 152

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-6 Input Jitter Tolerance When the input signal in the E1 interface is witho

Page 153

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-7 11.5. POTS Parameter FXO(COT POTS) FXS (RT POTS) Subscriber Phone Signa

Page 154

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-8 Parameter FXO (COT POTS) FXS (RT POTS) Net Loss 2.0 ± 0.75 dB End-to-E

Page 155

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-9 11.6. Pay Phones Parameters FXO-P (COT) FXS-P (RT) Subscriber Phone Signa

Page 156

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-10 Parameters FXO-P (COT) FXS-P (RT) Net Loss 20±75 dB End-to-End Return

Page 157

2. System Architecture MSAP2000 Technical Manual V3.0 2-4 Digital Leased Lines MSAP2000 provides various service modules for digital leased lines,

Page 158

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-11 11.7. 2W/4W E&M Interface Parameter 2W 4W Standard ITU-T G.712 Sig

Page 159

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-12 Figure 11-A Attenuation Frequency Distortion for the following Modules:

Page 160

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-13 Figure 11-C Signal-to-Total Distortion Ratio for the following Modules:

Page 161

11. System Parameter Specification MSAP2000 Technical Manual V3.0 11-14 Figure 11-E Attenuation/Frequency Distortion for the Following Module:

Page 162

2. System Architecture MSAP2000 Technical Manual V3.0 2-5 2.4. E1 Multiplexer Many Service Providers have already adapted SDH as the backbone of

Page 163

2. System Architecture MSAP2000 Technical Manual V3.0 2-6 2.5. IP DSLAM IP DSLAM MSAP2000 supports IP DSLAM functions. The uplink to BBRAS can be

Page 164

2. System Architecture MSAP2000 Technical Manual V3.0 2-7 2.6. Gigabit Switch Migration towards IP is the future trend of network development. M

Page 165 - 7.21. G.SHDSL Module (GSH)

2. System Architecture MSAP2000 Technical Manual V3.0 2-8 2.7. VoIP Gateway VoIP Gateway Along with the widespread usage of the Internet, VoIP de

Page 166

2. System Architecture MSAP2000 Technical Manual V3.0 2-9 VoIP Gateway at RT Service Providers with no existing facilities can easily deploy a br

Page 167

MSAP2000 Technical Manual V3.0 1 MSAP2000 Multi-Service Access Platform Copyright Copyright © 2004-2007 by ZyXEL Technologies Inc. The contents o

Page 168

2. System Architecture MSAP2000 Technical Manual V3.0 2-10 2.8. Layer 2 Switch Layer 2 switch MSAP2000 can connect to Edge router to provide Ethe

Page 169

2. System Architecture MSAP2000 Technical Manual V3.0 2-11 2.9. Digital Cross Connect MSAP2000’s Timeslot Interchange technology is based on VLS

Page 170

2. System Architecture MSAP2000 Technical Manual V3.0 2-12 2.10. Flexible Topology MSAP2000 supports various types of network topologies, such a

Page 171

2. System Architecture MSAP2000 Technical Manual V3.0 2-13 Ring MSAP2000 supports ring topology, with automatic protection switching (APS), . Pro

Page 172

2. System Architecture MSAP2000 Technical Manual V3.0 2-14 2.11. Local Craft Terminal MSAP2000 can be linked to PCs via its RS-232 interface, t

Page 173

2. System Architecture MSAP2000 Technical Manual V3.0 2-15 2.12. Network Management System OptiCore is a Network Management System (NMS) develo

Page 174

2. System Architecture MSAP2000 Technical Manual V3.0 2-16 THIS PAGE IS LEFT BLANK

Page 175

3. Application and Services MSAP2000 Technical Manual V3.0 i Table of Contents 3. Applications and Services ...

Page 176

3. Application and Services MSAP2000 Technical Manual V3.0 ii THIS PAGE IS LEFT BLANK

Page 177

3. Application and Services MSAP2000 Technical Manual V3.0 3-1 3. Applications and Services 3.1. Fiber to the Building (FTTB) When MSAP2000 is

Page 178

MSAP2000 Technical Manual V3.0 2 About This Manual This manual applies to the ZyXEL MSAP2000 Release 3. The main purpose of this manual is to ma

Page 179

3. Application and Services MSAP2000 Technical Manual V3.0 3-2 3.2. Fiber to the Curb (FTTC) As shown in the diagram below, when an environment

Page 180

3. Application and Services MSAP2000 Technical Manual V3.0 3-3 3.3. Fiber to the HOME (FTTH) As triple play services grow, providing higher ba

Page 181

3. Application and Services MSAP2000 Technical Manual V3.0 3-4 3.4. Optical Transportation Wireless service providers are ever-searching for sol

Page 182

3. Application and Services MSAP2000 Technical Manual V3.0 3-5 3.5. A One-Stop Solution for the Telephone Service Network MSAP2000 is a next gen

Page 183

3. Application and Services MSAP2000 Technical Manual V3.0 3-6 Single-end Configuration: Dual-end Configuration: Voice Over Packet Service Provi

Page 184

3. Application and Services MSAP2000 Technical Manual V3.0 3-7 3.6. Application for Data Leased Line Services In order to adhere to Quality of

Page 185

3. Application and Services MSAP2000 Technical Manual V3.0 3-8 3.7. Application for DSL Services xDSL over Optical Ethernet services possess t

Page 186

3. Application and Services MSAP2000 Technical Manual V3.0 3-9 Optical Gigabit Ethernet MSAP2000 supports Gigabit Ethernet (GbE) optic transmissio

Page 187

3. Application and Services MSAP2000 Technical Manual V3.0 3-10 3.9. Microwave radio application STM-1 electrical interface MSAP2000 supports micr

Page 188

3. Application and Services MSAP2000 Technical Manual V3.0 3-11 THIS PAGE IS LEFT BLANK

Page 189

MSAP2000 Technical Manual V3.0 3 Conventions The manual uses the following conventions: General conventions Convention Description Arial Norma

Page 190 - 7.29. Ethernet Module (ETH)

4. System Components MSAP2000 Technical Manual V3.0 i Table of Contents 4. System Components ...

Page 191

4. System Components MSAP2000 Technical Manual V3.0 ii THIS PAGE IS LEFT BLANK

Page 192

4. System Components MSAP2000 Technical Manual V3.0 4-1 4. System Components 4.1. Overview MSAP is a next generation Broadband Loop Carrier (BL

Page 193

4. System Components MSAP2000 Technical Manual V3.0 4-2 4.2. Terminal Central Office Terminal (COT) Each network has only one Central Office Te

Page 194

4. System Components MSAP2000 Technical Manual V3.0 4-3 4.3. Shelf MSAP2000 can be encased within any 19 or 23-inch rack, or any standard rack w

Page 195

4. System Components MSAP2000 Technical Manual V3.0 4-4 Slot MSAP2000’s common shelf is as shown in Figure 4-A. Each shelf includes 22 slots, and

Page 196

4. System Components MSAP2000 Technical Manual V3.0 4-5 When a QE1M is plugged into the 8th slot of RT5’s extension shelf, and assigned to be u

Page 197

4. System Components MSAP2000 Technical Manual V3.0 4-6 4.4. Common Control Modules MSAP2000’s Common Control Modules form the basis for the MSA

Page 198

4. System Components MSAP2000 Technical Manual V3.0 4-7 shelf’s EPM. The ELM’s Digital Cross Connect function can link any subscriber channel wit

Page 199

4. System Components MSAP2000 Technical Manual V3.0 4-8 4.5. Trunk Interface Module MSAP2000’s Trunk Interface Module uses copper wires, optic f

Page 200

Table of Contents MSAP2000 Technical Manual V3.0 i Table of Contents 1. System Introduction ...

Page 201

4. System Components MSAP2000 Technical Manual V3.0 4-9 QE1M provides performance monitoring functions, and it will generate Near and Far end perf

Page 202

4. System Components MSAP2000 Technical Manual V3.0 4-10 Current initiation, Voice Signaling transfer, and Tip-Ring Reversal (Polarity Guard) for

Page 203

4. System Components MSAP2000 Technical Manual V3.0 4-11 EoSM modules. Each shelf can have as many as 16 CEoSM to be used as uplink to Edge rou

Page 204

4. System Components MSAP2000 Technical Manual V3.0 4-12 4.7. Subscriber Interface Module MSAP2000 is a broadband network access platform, with

Page 205

4. System Components MSAP2000 Technical Manual V3.0 4-13 provides 8 lines of 2-Wire Analog Payphone Interfaces. FXS-P generates 12 KHz or 16 KHz

Page 206

4. System Components MSAP2000 Technical Manual V3.0 4-14 ETH The ETH (Ethernet Interface) Module provides 10 Base-T and 100 Base-T Auto-Negotiati

Page 207 - 8. System Management

4. System Components MSAP2000 Technical Manual V3.0 4-15 4.8. Subscriber End Facilities GSHDSL Modem (GSH-R) The GSH Module (G.SHDSL Line Card)

Page 208

4. System Components MSAP2000 Technical Manual V3.0 4-16 4.9. Indoor Rack The MSAP2000 chassis can be installed upon any 19 or 23-inch rack, or

Page 209 - 8.3. Telnet

4. System Components MSAP2000 Technical Manual V3.0 4-17 4.10. Outdoor Cabinet The MSAP2000 RT can also be installed inside a cabinet. The cabin

Page 210 - 刪除: ZyFLEX

4. System Components MSAP2000 Technical Manual V3.0 4-18 THIS PAGE IS LEFT BLANK

Page 211

Table of Contents MSAP2000 Technical Manual V3.0 ii 4.4. Common Control Modules...

Page 212

5. System Configuration MSAP2000 User Manual V3.0 i Table of Contents 5. System Configuration...

Page 213

5. System Configuration MSAP2000 User Manual V3.0 ii This PAGE is LEFT BLANK INTETIONAL

Page 214

5. System Configuration MSAP2000 User Manual V3.0 5-1 5. System Configuration MSAP2000 Modules are the basic elements for service provision.

Page 215 - 9. NMS Management Functions

5. System Configuration MSAP2000 User Manual V3.0 5-2 5.1. Slot Chart The following chart shows the module-slot allocation for MSAP2000 universal

Page 216 - 9.2. Configuration

5. System Configuration MSAP2000 User Manual V3.0 5-3 5.2. Module Capacity COT Side Module Slot NumberLines Note FXS 1~ 16 16 POTS connecti

Page 217

5. System Configuration MSAP2000 User Manual V3.0 5-4 RT Side Module Slot NumberLines Note FXS 1~ 16 16 POTS connecting subscriber’s CPE FX

Page 218 - 9.4. Fault Management (FM)

5. System Configuration MSAP2000 User Manual V3.0 5-5 5.3. 120 Lines A/B wire System Configuration (STM-1) Module Quantity COT RT Module Qty M

Page 219

5. System Configuration MSAP2000 User Manual V3.0 5-6 5.4. 240 Lines A/B wire System Configuration (STM-1) Module Quantity COT RT Module Qty M

Page 220 - 9.5. Maintenance

5. System Configuration MSAP2000 User Manual V3.0 5-7 5.5. 360 Lines A/B wire System Configuration (STM-1) Module Quantity COT RT Module Qty M

Page 221

5. System Configuration MSAP2000 User Manual V3.0 5-8 5.6. 480 Lines A/B wire System Configuration (STM-1) Module Quantity COT RT Module Qty M

Page 222

Table of Contents MSAP2000 Technical Manual V3.0 iii 7.2. Main Components ...

Page 223 - 9.6. Security

5. System Configuration MSAP2000 User Manual V3.0 5-9 5.7. 600 Lines A/B wire System Configuration (STM-1) Module Quantity COT RT Module Qty M

Page 224

5. System Configuration MSAP2000 User Manual V3.0 5-10 5.8. 720 Lines A/B wire System Configuration (STM-1) Module Quantity COT RT Module Qty

Page 225

5. System Configuration MSAP2000 User Manual V3.0 5-11 5.9. 960 Lines System Configuration (STM-1) Module Quantity COT RT Module Qty Module

Page 226 - Environment

5. System Configuration MSAP2000 User Manual V3.0 5-12 5.10. 1890 Lines System Configuration (STM-1) Module Quantity COT RT Module Qty Modu

Page 227 - 10.2. Environment Conditions

5. System Configuration MSAP2000 User Manual V3.0 5-13 RT Slot Allocation RT Extension Shelf Slot No.Main Shelf 1 2 3 4 5 6 7 1 FXS FXS FX

Page 228

5. System Configuration MSAP2000 User Manual V3.0 5-14 5.11. 120 POTS + 24 ADSL System Configuration (STM-1) Module Quantity COT Main Shelf R

Page 229

5. System Configuration MSAP2000 User Manual V3.0 5-15 5.12. 240 POTS + 48 ADSL System Configuration (STM-1) Module Quantity COT Main Shelf R

Page 230 - 11.1. STM-1

5. System Configuration MSAP2000 User Manual V3.0 5-16 5.13. 360 POTS + 72 ADSL System Configuration (STM-1) Module Quantity COT Main Shelf R

Page 231 - 11.2. STM-4

5. System Configuration MSAP2000 User Manual V3.0 5-17 5.14. 480 POTS + 96 ADSL V5 System Configuration (STM-1) Module Quantity COT Main Shelf

Page 232 - 11.3. Gigabit

5. System Configuration MSAP2000 User Manual V3.0 5-18 5.15. 480 POTS + 96 ADSL + 6 G.SHDSL V5 System Configuration (STM-1) Module Quantity CO

Page 233 - 11.4. E1

Table of Contents MSAP2000 Technical Manual V3.0 iv 9. NMS Management Functions...

Page 234

5. System Configuration MSAP2000 User Manual V3.0 5-19 5.16. 960 POTS + 120 ADSL + 4 G.SHDSL V5 System Configuration (STM-1) Module Quantity C

Page 235

5. System Configuration MSAP2000 User Manual V3.0 5-20 5.17. 1024 POTS + 96 ADSL + Single-ended V5 System Configuration Module Quantity COT

Page 236 - 11.5. POTS

5. System Configuration MSAP2000 User Manual V3.0 5-21 5.18. 480 POTS + 180 ADSL NGN System Configuration Module Quantity COT Main Shelf RT M

Page 237 - : > 15 dB

5. System Configuration MSAP2000 User Manual V3.0 5-22 5.19. 900 POTS + 180 ADSL + 2 G.SHDSL NGN System Configuration Module Quantity COT Main

Page 238 - 11.6. Pay Phones

5. System Configuration MSAP2000 User Manual V3.0 5-23 5.20. 460 POTS + 256 ADSL Single-ended NGN System Configuration Module Quantity COT Mai

Page 239

5. System Configuration MSAP2000 User Manual V3.0 5-24 5.21. 944 POTS + 192 ADSL Single-ended NGN System Configuration Module Quantity COT Mai

Page 240

6. System Design MSAP2000 Technical Manual V3.0 6-i Table of Contents 6. System Design ...

Page 241

6. System Design MSAP2000 Technical Manual V3.0 6-ii THIS PAGE IS LEFT BLANK

Page 242

6. System Design MSAP2000 Technical Manual V3.0 6-1 6. System Design 6.1. System Capacity MSAP2000 is designed to provide both capabilities

Page 243

6. System Design MSAP2000 Technical Manual V3.0 6-2 Module Name Subscriber Qty/Card Subscriber Qty/Shelf Subscriber Qty/System FXS 16 256 189

Commentaires sur ces manuels

Pas de commentaire