ZyXEL Communications P-330W V2 - V1.90 Manuel

Naviguer en ligne ou télécharger Manuel pour Routeurs ZyXEL Communications P-330W V2 - V1.90. ZyXEL Communications P-330W V2 - V1.90 Product manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 53
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
ABB solar inverters
Product manual
CDD (concentrator data device)
Vue de la page 0
1 2 3 4 5 6 ... 52 53

Résumé du contenu

Page 1 - Product manual

ABB solar invertersProduct manualCDD (concentrator data device)

Page 2 - SAVE THESE INSTRUCTIONS!

- 10 -006CC22 - Plan the installationSystem integrationThe diagram below shows several MICRO inverters communicating with a CDD, which in turn connect

Page 3 - BCG.00613.1_AA, NA Rev 1.0

- 11 -006CC22 - Plan the installationSelect the installation locationIt is recommended to undertake connection, conguration and acquisition operation

Page 4

- 12 -006CC22 - Plan the installationEvaluate the installation positionThe radio signal can be limited by obstacles and distance. In order to boost t

Page 5

- 13 -006CC22 - Plan the installationBefore permanently mounting the system it is important to consider the possible scenarios shown below and evaluat

Page 6

- 14 -006CC22 - Plan the installationMount the CDDIt is recommended to undertake all the conguration operations in part 4 before mounting

Page 7 - Intended use

- 15 -007CH3Connect the CDDIn order to operate the system, the CDD must be plugged into an electrical outlet and connected to a computer or router. Th

Page 8 - Regulatory nameplate

- 16 -008CC34 - Connect and congure the CDDWireless connection to the internetThe wireless connection of the CDD is enabled by default and requires a

Page 9

- 17 -008CC34 - Connect and congure the CDDSecure networks without a MAC address filterA security key, or passkey, is required to access the a secure

Page 10 - System integration

- 18 -008CC34 - Connect and congure the CDDDHCP configurationIf no wireless networks are found, it may be necessary to change the DHCP settings. The

Page 11 - 2 - Plan the installation

- 19 -008CC34 - Connect and congure the CDDWLess enabled NO >Ethernet connection to the internetWLess connectivity is enabled by default a

Page 12

- 2 -001CVIMPORTANT SAFETY INSTRUCTIONSThis manual contains important safety instructions that must be followed during installation and maintenance of

Page 13

- 20 -008CC34 - Connect and congure the CDD2. Direct to the computer using an Ethernet cableThis type of connection should only be used for

Page 14 - Mount the CDD

- 21 -009CH4LED and display operationsThe status of the inverter is indicated by the constant or intermittent lighting of the LED located on the front

Page 15 - Connect the CDD

- 22 -010CC44 - CDD display operationsDescription of the display menusThe CDD display consists of 2 lines with 16 characters per line. The operating

Page 16 - A052725AF5222 >

- 23 -010CC44 - CDD display operations• Access the three MAIN menus fron the GENERAL INFORMATION display by pressing the UP and DOWN buttons together

Page 17 - Autoconnection configuration

- 24 -010CC44 - CDD display operationsGeneral Information cyclical displayBasic information menuMain menu - StatisticsGENERAL INFORMATION cyclical dis

Page 18 - IP address view

- 25 -010CC44 - CDD display operationsMain menu - View informationMain menu - Change settingsMAIN menus Statistics of the system and each inverter V

Page 19

- 26 -010CC44 - CDD display operations

Page 20 - Firmware upgrade

- 27 -011CH5Acquisition process The acquisition of the MICRO Inverters by the CDD can be performed directly from the CDD display or with a PC or Table

Page 21 - LED and display operations

- 28 -011CC55 - Acquire the MICRO invertersScanning for inverters to acquire begins after the Geo position and Timezone have been entered as shown on

Page 22 - 4 - CDD display operations

- 29 -011CC55 - Acquire the MICRO invertersSelect MicroManagerfrom the drop-downCONFIG menu on the Home pageAuthentication is requiredEnter the defaul

Page 23

- 3 -001CVProduct ManualCDD - concentrator data device1 - Introduction and safety2 - Plan the installation3 - CDD display operations4 - Connect and co

Page 24 - Main menu - Statistics

- 30 -011CC55 - Acquire the MICRO invertersClick START ACQUISITIONto begin scanningThere is no timeout for the acquisition procedure. Click on STOP A

Page 25 - Main menu - Change

- 31 -011CC55 - Acquire the MICRO invertersSelect Country Standardfrom the drop-down menu Press CONFIRM• If the link to register the CDD has been sel

Page 26

- 32 -011CC55 - Acquire the MICRO inverters

Page 27 - Acquisition process

- 33 -012C6Remote monitoring on the Easy View web portalWhen the acquisition of the MICRO Inverters is complete, it is possible to congure the remote

Page 28 - *; number

- 34 -012C6The registration process is completed in three steps:Step 1.• Enter personal contact information.• Enter an email account.• An email wit

Page 29 - Home page

- 35 -012C6Aurora vision plant viewerAurora Vision Plant Viewer is a free software that offers remote plant monitoring through the internet. The port

Page 30 - Click START ACQUISITION

- 36 -012C66 - System monitoringLocal monitoring using the CDD web serverIn order to access the CDD local web server, a PC or tablet must be connected

Page 31 - Click here to complete the

- 37 -012C66 - System monitoringVIEW menuView > Info: displays information for plant, system, date/time and network.Use scroll bar toview more dat

Page 32

- 38 -012C66 - System monitoringCONFIG menuSelecting Cong on the menu bar gives access to eight drop-down menus. Cong > Plant: used to modify p

Page 33 - Self-registration procedure

- 39 -012C66 - System monitoringCong > CS param: modication of country standardCong > Ground/Fault/Energy: options to reset ground fault an

Page 34

- 4 -002TCContentsIntroduction and safety ...

Page 35 - Aurora vision plant viewer

- 40 -012C66 - System monitoringEVENTS menuA log of system events relating CDD and inverters is displayed in the Events menu. This includes errors (E

Page 36 - HOME page

- 41 -012C66 - System monitoringBrowse to location on computerwhere firmware files have beendownloaded and savedOpen file and select UploadStep 1Load

Page 37 - VIEW menu

- 42 -012C66 - System monitoringuP MICROinv Fw: used to update the microproccesor rmware of the CDD. The rmware must rst be downloaded and saved

Page 38 - CONFIG menu

- 43 -013C7The MICRO inverter systemThis system is composed of a group of MICRO Inverters that convert direct electric current from a photovoltaic mod

Page 39 - Confirm to change

- 44 -013C77 - AppendixDescription of the CDD The Power-One MICRO Inverters associated with the CDD are monitored using CDD display, the CDD web serve

Page 40 - UPGRADE menu

- 45 -013C77 - AppendixDisplay codeLED status MessageCause SolutionE006 blinking redOutput OC The error appears when the in-verter output current exce

Page 41 - CDD Local Upgr.:

- 46 -013C77 - AppendixDisplay codeLED status MessageCause SolutionE018 blinking greenGround fault The error is generated when a ground leakage curren

Page 42 - HELP menu

- 47 -013C77 - AppendixDisplay codeLED status MessageCause SolutionE051Solid redCountry Not Comp The set grid standard is not com-patible with the rm

Page 43 - The MICRO inverter system

- 48 -013C77 - AppendixDisplay codeLED status MessageCause SolutionW003 Blinking greenGrid Fail W004Blinking greenVAC OVW005Blinking greenVAC UVThis a

Page 44 - Alarm messages and codes

- 49 -013C77 - AppendixMaking a service callCall technical support at 877-261-1374 and provide the following information to initiate a call:• Model n

Page 45 - 7 - Appendix

- 5 -002TCSystem monitoring ...

Page 46

- 50 -013C77 - AppendixWireless routers compatible with CDDBelow is the list of wireless routers tested for compatibility with CDD rmware 2.1.3 or la

Page 47

- 51 -013C77 - AppendixVendor Model FW Version NetGear WG103 WG103_V2.0.25 NetGear WGR614v9 V1.0.9_1.0.1NA NetGear WGT624 v3 NetGear WGT624v2

Page 48

Further informationFor more information on ABB products and services for solar applications, navigate to www.abb.com/solarinverters

Page 49 - Technical data and types

Contact uswww.abb.com/solarinvertersCDD Product ManualBCG.00613.1_AA (NA REV 1.0)© Copyright 2014 ABB. All Rights Reserved.YOUR ABB DISTRIBUTORSOLIG

Page 50

- 6 -002TC

Page 51

- 7 -003CH1Warnings in this documentThis is a list of special safety symbols used in this manual that highlight potential safety risks and/or useful i

Page 52 - Further information

- 8 -004CC11- Introduction and safetyAvailable versionsThe CDD described in this manual is available in a single version suitable for all countries of

Page 53 - Contact us

- 9 -005CH2Description of the CDDThe ABB MICRO Inverters associated with the CDD can be monitored using the CDD display, the CDD web server interface,

Commentaires sur ces manuels

Pas de commentaire