(6) Device will crash immediately.
9. [BUG FIX]
Symptom: ZyWALL WLAN & DMZ ports cannot work in dynamic VLAN ports.
Condition:
(1) Restore default romfile.
(2) Set Port Roles as 1>LAN, 2>LAN, 3>DMZ, 4>WLAN.
(3) Set DMZ IP as 10.10.2.1/24, DHCP as None.
(4) Set Wireless Card bridge to WLAN.
(5) Unplug wireless card and reboot device.
(6) PC connects to DMZ port, IP is 10.10.2.100/24 and gateway is 10.10.2.1, and the
PC ping 10.10.2.1 will fail.
10. [BUG FIX]
Symptom: The eWC>Firewall>Default Rule page will popup JavaScript error in router
mode.
Condition:
(1) Go to eWC>FIREWALL>Default Rule page.
(2) Click Reset button, ZyWALL pop-ups a JavaScript error.
11. [BUG FIX]
Symptom: Unknown crash.
Condition:
(1) Restore default romfile.
(2) Switch device to Active/Active mode, and confirm WAN1 and WAN2 can work
fine.
(3) Set WAN2 ping check point to User-defined.
(4) After a while, the device sometimes will crash.
12. [BUG FIX]
Symptom: IDP Total Sessions Scanned is wrong.
Condition:
(1) Enable AV, SMTP service and enable all directions.
(2) Enable IDP, but disable all traffic direction.
(3) Attacker sends the mail containing virus to victim via ZyWALL to check if
Anti-Virus can detect viruses.
(4) In eWC>REPORTS>THREAT REPORTS, Total Sessions Scanned of IDP will
count number. But it should not.
13. [BUG FIX]
Symptom: ZyWALL crashes if you try to backup Configuration AV or IDP.
Condition:
(1) Go to eWC>Security>ANTI-VIRUS(or IDP)>Backup & Restore page.
(2) Click Backup or Restore button.
(3) System will crash sometimes.
14. [BUG FIX]
Symptom: The ZyWALL should use user configured time server to do daily time
adjustment.
Condition:
(1) Reboot the ZyWALL, set 'abc.abc.edu' as user defined 'Time Server Address'.
(2) The time synchronization will fail at start-up and use the default built-in time