ZyWALL 2 User’s Guide
Remote Management 35-3
Table 35-1 Menu 24.11 – Remote Management Control
FIELD DESCRIPTION EXAMPLE
Once you have filled in this menu, press [ENTER] at the message "Press ENTER to Confirm or ESC to
Cancel" to save your configuration, or press [ESC] to cancel.
35.1.1 Remote Management Limitations
Remote management over LAN or WAN will not work when:
1. A filter in menu 3.1 (LAN) or in menu 11.5 (WAN) is applied to block a Telnet, FTP or Web
service.
2. You have disabled that service in menu 24.11.
3. The IP address in the Secure Client IP field (menu 24.11) does not match the client IP address. If
it does not match, the ZyWALL will disconnect the session immediately.
4. There is already another remote management session with an equal or higher priority running. You
may only have one remote management session running at one time.
5. There is a firewall rule that blocks it.